Relay for LRA-DCRX Receiver

Using the Relay on the LRA-DCRX to Connect External Device
LRA-DCRX Receiver Relay Image The LRA-DCRX receiver features a relay that may be used to integrate and activate an external device.  For example, a strobe light, 12V DC output, or other devices may be configured to trigger when the relay on the receiver activates. Tips & Notes:
  • The unit WILL NOT supply power to the external device.  The external device must have a separate power supply.
  • The relay ONLY works with Zone 4 on the receiver.  For the relay to work, there must be a transmitter paired with Zone 4.
  • The relay DOES NOT provide power.LRA-DCRX Relay Diagram
  • The relay may be set to normally open or normally closed.
  • Ensure the relay is set to the “on” position.
  • Set the duration of output to 2 seconds or 5 seconds.
In this example we will wire a 12V DC siren to sound when the push button paired to Zone 4 is triggered. What you will need:
  • A LRA trasmitter (push button, door contact, etc.) paired to zone 4 of the LRA-DCRX receiver.
  • 12V DC siren
  • Extra wire (as needed)
  • External power device used to power the 12V DC siren.  In this example we are using a 16.5 VAC /40VA Class II plugin transformer.  Please make sure the power supply you use will supply the necessary power to the external device.
  1.  Ensure the power supply is unplugged.
  2. Wire one wire of the siren into one of the “normally open” connectors on back of the receiver (see image below).
  3. Wire the other wire of the siren to the plug-in transformer (see image below).
  4. Take a wire and connect one end into the other slot of the “normally open” relay.
  5. Take the other end of that same wire and connect it to the transformer (see image below).
  6. Plug in the transformer.  Ensure the receiver is powered on–test.
LRA-DCRX Relay Wiring to External Device-Updated